Journals →  Chernye Metally →  2017 →  #12 →  Back

Machine-building Technologies
New developments of Tula State University
ArticleName Metrological provision of testing of magnetic materials
ArticleAuthor O. I. Boriskin, D. I. Blagoveshchensky, N. P. Ezhova, G. A. Nuzhdin, A. S. Perminov
ArticleAuthorData

Tula State University (Tula, Russia):

Boriskin O. I., Dr. Eng., Prof., Head of the Chair of Instrumental and Metrological Systems, Director of Polytechnic Institute

 

State Regional Center for Standardization, Metrology and Testing in Tula Region (Tula, Russia):
Blagoveshchensky D. I., Cand. Eng.

 

Central Scientific and Research Institute of Chemustry and Mechanics named after D. I. Mendeleev (Moscow, Russia):
Ezhova N. P.


National University of Science and Technology “MISiS” (Moscow, Russia):
Nuzhdin G. A., Cand. Eng., Associate Prof., E-mail: nuzhdin.65@mail.ru
Perminov A. S., Mag. Eng., Dr., University Assistant

Abstract

The dynamic testing technique of the soft magnetic materials has developed. The technique in accordance with GOST R 51672–2000 is taken as the basic one with additions of sections in compliance with requirements of GOST R 8.563–2009 and GOST R 8.820–2013. Requirements of GOST R 8.820–2013 are applying in development of the methodical documents regulating metrological support of measurements. This standard contains the new approaches coordinated with ISO 9001, now the developed technique includes 15 sections. The dynamic testing technique was approved on the multipurpose MV-MM unit, on two principally different types of the soft magnetic materials: Mn–Zn ferrite 2000 NM and Fe–Ni permalloy 79NM. The MV-MM installation is intended for research of characteristics of soft magnetic materials and their parameters. It allows to take a magnetic hysteresis loop measurements in fields with stress up to 800 A/m with frequencies 10–2000 Hz. Ring samples are demagnetized in alternating field with uniformly decreasing amplitude before determination of all magnetic characteristics, except limit hysteresis loop or its parameters. Rectangular samples don’t demagnetize. The field is created by current in the magnetizing winding of a sample or in the magnetizing device replacing this winding. The carried-out approbation of the dynamic testing technique on the samples of two types of the soft magnetic materials (soft ferrite and permalloy) has confirmed its applicability and has shown expediency of application of the agreed requirements of three above-mentioned standards.

keywords Metrological support, soft magnetic materials, measurement of magnetic properties, soft ferrite, permalloy, testing technique, demagnetizing, dynamic characteristics
References

1. Burzo E., Codescu M. M., Kappel W., Helerea E. Magnetic Materials for Technical Applicatios. Journal of Optoelectronics and Advanced Materials. 2009. Vol. 11, Iss. 3. pp. 229–237.
2. Kijima H., Zhang Y., Ohnuma S., Masumoto H., Kobayashi N., Muralt P., Setter N. (Co–Ti–O)/Bi–Ti–O Multilaier Films with High-Frequency Electromagnetic Response. Japanese Journal of Applied Physics. 2013. Vol. 52, Iss. 9 PART2. pp. 09KA14. DOI: 10.7567/JJAP.52.09KA14
3. Steentjes S., Hameyer K., Zirka S. E., Moroz Y. E., Moroz E. Y. Dynamic Magnetization Model of Nonoriented Steel Sheets. IEEE Transactions on Magnetics. 2014. Vol. 50, Iss. 4. pp. 6786432.
4. Sun Z., Li L., Schnabel A., Reisner M., Fierlinger P., Stuiber S. Dynamic Modeling of the Behavior of Permalloy for Magnetic Shielding. Journal of Applied Physics. 2016. Vol. 119, Iss. 19. pp. 193902.
5. Vvedenskiy V. Yu., Nuzhdin G. A., Sokolova N. A. Metrology of nanocrystal and amorphous alloys properties. Nanoinzheneriya. 2014. No. 12. pp. 44–48.
6. Lechner W., Puff W., Wilde G., Wurschum R. Vacancy-type defects in amorphous and nanocrystalline alloys: Variation with preparation route and processing. Scripta Materialia. 2010. Vol. 62, Iss. 7. pp. 439–442.
7. GOST R 51672–2000. Metrological ensuring of product testing for the assurance of conformity. General principles. State Standard. Moscow : Standartinform, 2008. 21 p.
8. Vvedenskiy V. Yu., Nuzhdin G. A. Control of stability of measurements of magnetic properties of alloys. Nanoinzheneriya. 2015. No. 11. pp. 35–41.
9. Anisimova M. A., Blagoveshchenskiy D. I., Nuzhdin G. A. Metrological Support in NDT Equipment Production. Kontrol. Diagnostika. 2017. No. 7. pp. 50–55.
10. GOST R 8.820–2013. State system for ensuring the uniformity of measurements. Metrological assurance. General. Moscow : Standartinform, 2014. 16 p.
11. GOST R 8.563–2009. State system for ensuring the uniformity of measurements. Procedures of measurements. Moscow : Standartinform, 2011. 20 p.
12. Fulmek P., Haumer P., Holler G., Wegleiter H., Schweighofer B. Method for the Measurement of Transient Magnetic AC Properties of Soft Ferrites. IEEE Transactions on Magnetics. 2010. Vol. 46, Iss. 2. pp. 463–466.
13. Roshen W. A. Magnetic Loss in Soft Ferrites. Journal of Applied Physics. 2007. Vol. 101, Iss. 9. pp. 09M522. DOI: 10.1063/1.2712056
14. GOST R 8.377–80. State system for ensuring the uniformity of measurements. Soft-magnetic materials. Methods of determination of static magnetic characteristics. Moscow : Izdatelstvo standartov, 1980. 25 p.
15. Oxley P. Apparatus for Magnetization and Efficient Demagnetization of Soft Magnetic Materials. IEEE Transactions on Magnetics. 2009. Vol. 45, Iss. 9. pp. 3274–3283.
16. Graham C. D., Lorenz B. E. Demagnetizing factors for disk samples of non ideal soft magnetic materials. Journal of Applied Physics. 2010. Vol. 107, Iss. 9. pp. 09A322. DOI: 10.1063/1.3347916.
17. GOST 10160–75. Magnetically soft precision alloys. Specifications.